FMEA ==== The FMEA is done on the "first zoom level" of the architecture, the :ref:`main workflow `. The relevant elements are annotated by oval labels, see also the :ref:`diagram legend `. Fault Model ----------- The following analysis is based on this generic *fault model* for activity diagrams: .. list-table:: :header-rows: 1 :widths: 20 15 65 :width: 100% * - Element Type - Error ID - Generic Error Description * - Data storage - DS1 - Stored data changed before read operation * - - DS2 - New data not stored / keeps old data / stuck at specific value * - Data flow - DF1 - Transferred data changed * - - DF2 - Transferred data lost * - - DF3 - Data stored at / read from wrong location in data store * - - DF4 - Data transferred to wrong data store * - Processing - PR1 - Calculates wrong results * - - PR2 - Processing is skipped * - - PR3 - Processing too slow/fast * - Control flow - CF1 - Control flow stops * - - CF2 - Control flow proceeds to wrong process If more than one error is identified for the same element with the same error ID, a counter is added, e.g. `PR1.1`, `PR1.2`, etc. In the following sections, references to files are shown which end with ``_spec.rb``. These files are test files which can be found in the ``spec`` folder of the *dox_trace* extension, e.g. ``/spec/asil_spec.rb``. Generalized Errors ------------------ The following errors are analyzed generically and not on architectural element level. .. csv-table:: :file: fmea/general.csv :header-rows: 1 :widths: 12 30 32 :width: 100% :delim: , .. _fmea_command_line_workflow: Main Workflow ------------- This analysis is done on the :numref:`workflow_main_fig` with the :ref:`use_cases` in mind. .. csv-table:: :file: fmea/dynamic.csv :header-rows: 1 :widths: 5 5 25 35 25 :width: 100% :delim: ,